

- #Plate solving software for maxim dl 5 full version
- #Plate solving software for maxim dl 5 install
- #Plate solving software for maxim dl 5 full
- #Plate solving software for maxim dl 5 windows
Sub-Frame: Size of frame to use for plate solve exposures: Full Frame, Half Frame or Quarter Frame.Filter: Filter to use for plate solve exposures.Binning: Binning of plate solve exposures.Exposure: Length of plate solve exposures in seconds.The Plate Solving DEFAULT Setting panel of the Plate Solve Setup workspace contains default exposure settings for plate solving: If the distance between the telescope position reported by the mount and the position reported by plate solving is under 300 arc minutes, a sync would be done, otherwise the sync would not be done.In this example, if the Enable Sync Distance Check Watchdog checkbox were checked: Max Distance Allowed: The maximum allowed distance between the current telescope position as reported by the mount and the position returned by plate solving for a sync to be done.Enable Sync Distance Check Watchdog: If checked, the sync distance watchdog for Sequences is enabled.If enabled, this adds a new Sync watchdog to sequences which limit the maximum acceptable distance for which a sync can be done after plate solving. If the checkbox is set, then if a precision pointing plate solve fails, try again using the blind solver.If you have blind solver we suggest to switch on this flag Use Blind Solving if Plate Failed on Precise Pointing: Voyager uses plate solving to achieve precise pointing.Profile Setting (+/-): If the checkbox is checked, then if the image resolution scale returned by the plate solver differs from the profile setting of image scale by this percentage or more, consider it an error The Plate Solving Watchdog panel of the Plate Solve Setup workspace contains information used to verify information returned by the plate solver and whether to attempt failover to blind solving: Retry on Error: The number of times to retry the plate solve if it fails.The PinPoint LE, PlateSolve2 panel of the Plate Solve Setup workspace contains parameters used by these plate solvers: Max Solve Time: Maximum time in seconds beyond which Voyager will consider the plate solve operation to have failed.The ASPS, PlateSolve2, PinPoint LE & Full Setup panel of the Plate Solve Setup workspace contains parameters used by all these plate solve products. Here's the list of catalogs usable by PinPoint:ĪSPS, PlateSolve2, PinPoint LE & Full Setup Maximum catalog magnitude: Magnitude of the dimmest star in the selected star catalog.Path: Click the folder icon to browse for the path where the selected star catalog is installed.The catalog must be installed and accessible from PinPoint. Catalog: Choose the star catalog you want to use with PinPoint from the drop-down list.
#Plate solving software for maxim dl 5 full version
The PinPoint Full Setup panel of the Plate Solve Setup workspace contains parameters needed if you use PinPoint Full version for plate solving: After this operation please activate the flag "Use All Sky Image Link for scripted Imge link" in TheSkyX application, menù Tools->ImageLink tab AllSky
#Plate solving software for maxim dl 5 install
Important Note! In order to use TheSkyX ImageLink AllSky you must download from your Software Bisque subscription the AllSky Database and install in folder Documents\SoftwareBisque\Astrometry. It is very good at solving images but your image must be uploaded so it requires an Internet connection: PlateSolve2 is a product of Planewave Instruments: TheSkyX ImageLink is a component of TheSkyX from Software Bisque:
#Plate solving software for maxim dl 5 windows
PinPoint LE is a limited edition of PinPoint, bundled with MaximDL: Īll Sky Plate Solver uses the engine and runs it on a local Windows system under Cygwin: The choices include None, TheSkyX ImageLink All Sky, All Sky Plate Solver, and ASTAP.

PLATE Solve: Select the plate solve software that Voyager should use for plate solving when the field's RA and DEC is known (at least approximately).The Plate Solve panel of the Plate Solve Setup workspace is where you select your choice of plate solver and blind solver: The Plate Solve Setup workspace contains configuration information for the various plate solving software that Voyager can use: Red: Use extreme care when changing this setting - the wrong value can damage your equipment or the imaging session may fail.Gold or Yellow: Use caution when changing as things may not work well or as expected.Throughout the Setup workspace, Voyager uses color to indicate the following: 9 Plate & Blind Solving DEFAULT Setting.

